Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the acf domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/lnnoijhw/public_html/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woo-product-filter domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/lnnoijhw/public_html/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/lnnoijhw/public_html/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/lnnoijhw/public_html/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the bridge domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/lnnoijhw/public_html/wp-includes/functions.php on line 6131
Equiptrades | Shop

600 KVA Mahindra Generator

  • 600 KVA Prime (Closed type) Mahindra Diesel Generating set closed coupled with Stamford Alternator with standard accessories.

Inquiry Now
Genset Prime Rating (kVA) * 625
Genset Prime Rating (KW) 500
Phase / Voltage (V) 3/415
Power Factor 0.8 (lagging)
Current (A) 869
Frequency (Hz)& RPM 50/1500
Governing class G2 as per
ISO 8528 Part V
Starting system 24 V DC Electrical
Fuel tank capacity (lit) 900
Genset dimensions w/o silencer (mm) (L x W x H) approx. 5950x2000x2350
Genset Weight (kg) approx. 7500
Engine Specification
Make / Series
Engine Model 2806D-E18TAG 1A
Rated Power at 100% Load @ 1500 RPM (kW) 540
Aspiration Turbo Charged After Cooled
No. of cylinders 6
Bore x Stroke (mm) 145*183
Displacement (Lit) 18.1
Fuel consumption @ 75% load (lit/hr)^ 97
Fuel consumption @ 100% load (lit/hr)^ 130
Total lubrication system capacity (lit) 71
Lube oil consumption @ 100% load* 0.10% of fuel consumption
Lube oil change period (hrs.)
Radiator coolant capacity (lit) 55.6
Alternator
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%
  • Supplied with all Standard Accessories  i.e. Genset Controller, Battery & leads, Anti-Vibration pads, Safety Switches for LLOP, HWT etc. ( For More information please refer Brochure attached).
Weight 7500 kg
Dimensions 595 × 200 × 235 cm
Open and Closed Type

Phase

SKU: ET600MGEN3 Category: Tags: ,